Here on the coast of Maine and New Hampshire marinas are a major business and employer. Due to the nature of the business marinas most often have much of their property over water and this presents a unique Fire Protection situation. NFPA 303, Fire Protection Standard for Marinas and Boatyards is the standard for all marinas and boatyards along with NFPA 1 chapter 28. These standards are so specialized they often confuse both operators and local fire departments. So, let’s go over some of the highlights and issues with these unique businesses.

These protection standards cover the operations and construction of marinas, boatyards, yacht clubs, boat condominiums, docking facilities associated with residential condominiums, multiple docking facilities as a multifamily residence and all associated peers and floats. These standards also cover all support facilities in structures used for construction repair, storage hauling and launching or fueling of vessels. (NFPA 1 2018)
The first question most people ask is how would you put a fire out on a pier over the water? Some of our larger communities in Maine and New Hampshire have fire boats and they’re able to navigate into the Marina and quickly extinguish any fire. However, most of New England does not have such an asset. Standards quickly addressed fire department access both for storage outside on dry land, in the water and even inside buildings. Fire department access in the simplest terms is a fire department’s ability to drive their fire truck to the fire. In marinas and boatyards typically 150 feet is the standard for both storage inside buildings, outside buildings and on the water. For piers and docks that are floating the fire department must be able to drive the fire truck close enough that the hose lay from the fire apparatus does not exceed 150 feet. If the distance is more than 150 feet a Class 1 standpipe must be installed.
Another way to ensure fires can be put out is access to portable fire extinguishers. ABC fire extinguishers are required to be installed every 75 feet of travel distance on piers. The fire extinguishers also need to be protected from the environment here in New England. That is achieved most of the time either with a cover or in a box is especially designed to protect fire extinguishers.
Egress is another concern in boatyards and marinas. Like any other building there needs to be safe ways for people to exit the area. Luckily the code covers this by requiring that electrical lighting should be provided to ensure adequate illumination for all exterior area’s piers and floats, but should not be in a color or so bright that they interfere with navigational beacons.

Marinas and boatyards have some of the more complicated code issues that can arise for both the operators and local governments. If you have any questions or need help please give us a call here at Coastal Code Consultants to ensure your marine business is up to code. Anywhere in New England, Maine, New Hampshire, Massachusetts, Vermont or New York.
References
NFPA. (2017). NFPA 1 Fire Code 2018 ED. Quincy: NFPA.